 Domestic Boilers.

The Multi Fuel Domestic Boilers are intended to be installed in ground premises with a possibility of easy refuelling with Coal or Wood They are produced solely for Central Heating with a natural or forced circulation of the heating water.

Domestic Boiler Range.

 

MA 18- 18kw Boiler- 1 kw Localised area Heat

 

GA 26- 26kw Boiler- 2 kw Localised area Heat

 

GA 33- 33kw Boiler- 3 kw Localised area Heat

 

The LB- 40kw Boiler- 5 kw Localised area Heat

 

DOMESTIC BOILER  INSTALLATION INSTRUCTIONS

The Domestic boiler must be installed on a stable fireproof horizontal floor.  To protect the floor, a stable fireproof base can be used. The base must come out from the Wood Boiler Stove  least 50 cm in front and 30 cm at the side.

A clearance of 80 cm is required from the boiler for any combustible objects.

Before connecting the Domestic boiler  Stove to the chimney, consult a specialist.

The connecting elements (rosette and chimney) must be fixed tightly and firmly, so that they may not get into in the passage section. The flue pipes should have the same size as the connecting pipe of the boiler.

It is advisable that the Boiler  Stove work with a separate chimney.  If  other heating appliances are connected to the same chimney, it must be calculated for .

Fresh air must get in the boiler at least 4 Cubic Metres per hr  for each kilowatt from its heat output. When necessary a flow from adjacent premises or outside air must be  ensured

The burning process of the Domestic Boiler Stove must not feel shortage of air on the action of gravitational or forced aspirations, since this is a prerequisite for insufficient combustion or returning of  flue gases in the premises

 

GENERAL RULES AND RECOMMENDATIONS

 

1. Before the building of the installation, it is recommended that the heat losses be calculated by a specialist for the concrete case.

2. The installation must be connected to the atmosphere with an  open expansion vessel when the system is open.

3. De-aeration of each branch and element of the installation in each moment of its operation shall be ensured

 